WS-C3650-24PD-S Specification
|
Enclosure type |
Rack-mountable – 1U |
Ports |
24 x 10/100/1000 (POE+) + 2 x 10G SFP+ & 2 x 1G SFP |
Network management Interface |
● Ethernet management port: RJ-45 connectors, 4-pair Cat-5 UTP cabling
● Management console port: RJ-45-to-DB9 cable for PC connections |
Available PoE Power |
390W |
Switching Capacity |
88Gbps |
Maximum stacking number |
9 |
Stack Bandwidth |
160Gbps |
Forwarding Performance |
68.45Mpps |
FNF entries |
24000 |
Maximum VLANs IDs |
4,094 |
Maximum VLANs IDs |
32K |
CPU |
Multicore CPU |
RAM |
4 G |
Flash Memory |
2 G |
Wireless |
Number of AP per switch/stack |
50 |
Number of wireless clients per switch/stack |
1000 |
Total number of WLANs per switch |
64 |
Wireless bandwidth per switch |
up to 20Gbps |
Supported Aironet AP series |
3700, 3600, 3500, 2600, 1600, 1260, 1140, 1040 |
Expansion / Connectivity |
Console ports |
USB (Type-B), Ethernet (RJ-45) |
Expansion Slot(s) |
power redundant slot |
Accessory & Rack Moubt Kits |
●ACC-KIT-T1: Accessory kit
●RACK-KIT-T1: Rack mount kit
●4PT-KIT-T1: Extension rails and brackets for four-point mounting |
Stacking module & cable |
●C3650-STACK-KIT: Stack Module
●STACK-T2-50CM: StackWise-160 stacking cable with a 0.5 m length
●STACK-T2-1M: StackWise-160 stacking cable with a 1.0 m length
●STACK-T2-3M: StackWise-160 stacking cable with a 3.0 m length |
Power supply |
PWR-C2-640WAC |
Power Device |
Power supply – redundant – plug-in module |
Power Redundancy |
optional |
Voltage range (Auto) |
100V-240V |
Power Consumption of standalone (in Watts) |
101.5 (max) |
Miscellaneous |
Width |
17.5 Inches (44.5 Cm) |
Depth |
17.625 Inches (44.8 Cm) |
Height |
1.73 Inches (4.4 Cm) |
Shipping Weight |
17.49 Kg |
Rack Mounting Kit |
optional |
MTBF in hours |
528,280 |
Compliant Standards |
● IEEE 802.1D Spanning Tree Protoco
● IEEE 802.1p CoS Prioritization
● IEEE 802.1Q VLAN
● IEEE 802.1s
● IEEE 802.1w
● IEEE 802.1X
● IEEE 802.1X-Rev
●IEEE 802.11
● IEEE 802.1ab (LLDP)
● IEEE 802.3ad
● IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports● IEEE 802.3 10BASE-T
● IEEE 802.3u 100BASE-TX
● IEEE 802.3ab 1000BASE-T
● IEEE 802.3z 1000BASE-X
● RMON I and II standards
● SNMP v1, v2c, and v3 |
System software / license |
System software |
IOS IP Base (Upgradable) |
EnergyWise license |
ENERGY-MGMT, ENERGY-MGT-100-K9 |
Software license |
●C3650-24-S-E: IP Base to IP Services RTU paper license
●L-C3650-24-S-E: IP Base to IP Services RTU electronic license |
Access Point Licenses |
●L-LIC-CT3650-UPG: Primary upgrade license SKU for Cisco 3650 wireless controller (e-delivery)
●L-LIC-CTIOS-1A: 1 access point adder license for Cisco IOS Software based wireless controller (e-delivery)
●L-LIC-CTIOS-1A: 1 access point adder license for Cisco IOS Software based wireless controller (e-delivery)
●LIC-CTIOS-1A: 1 access point adder license for the Cisco IOS Software based wireless controller (paper license) |
features |
●RPS Support ● Jumbo Frames ● VLANS ●Voice Vlan ●VTPv2 ●CDPv2 ●LLDP ● 802.3ad LACP and PAgP ● PVST/PVST+ ● 802.1W/802.1S ●Port Fast/Uplink Fast ●Dynamic Trunking Protocol (DTP) ● port CoS Trust and Override ● Trusted Boundary ● ACL Classification ●ingress Policing ● Auto QoS ● Per VLAN policies ● 802.1p queues ● Scheduling ● Priority Queuing ● Configure CoS Priority Queues ●Configure CoS Priority Queues ● Configure Queue Weights ● Configure Buffers and Thresholds ●Class & Policy Maps ● Modify CoS and DSCP Mapping ● Weighted Tail Drop ● IGMPv1,v2,v3 and MLDv1, v2 ● DHCP server ● DSCP transparency ● HSRP, VRRP ● RIPv1, v2 EIGRP stub, PIM stub, OSPF stub ● IPV6 management |
Advanced Network security |
● Port security ● DHCP snooping ●Dynamic ARP inspection (DAI) ● IP source guard ●The Unicast Reverse Path Forwarding (uRPF)
● Bidirectional data support on a SPAN ● User authentication
● Private VLAN ●Router and VLAN ACLs ● complete identity and security
● Multidomain authentication ● MAC address notification
● IGMP filtering ● Cisco security VLAN ACL
● Secure Shell (SSH) Protocol, Kerberos, and Simple Network Management Protocol Version 3 (SNMPv3)
● Port-based ACLs ● TrustSec SXP ● IEEE 802.1ae
● TACACS+ and RADIUS authentication ● Cisco standard and extended IP security router ACLs
● Bridge protocol data unit (BPDU) Guard
● Spanning Tree Root Guard (STRG) ● Wireless end-to-end security |
Management |
●BRIDGE-MIB ●CISCO-AUTH-FRAMEWORK-MIB
●CISCO-BGP4-MIB, BGP4-MIB ●CISCO-BRIDGE-EXT-MIB
●CISCO-BULK-FILE-MIB ●CISCO-CABLE-DIAG-MIB
●CISCO-CALLHOME-MIB ●CISCO-CEF-MIB
●CISCO-CIRCUIT-INTERFACE-MIB
●CISCO-ENTITY-VENDORTYPE-OID-MIB
●CISCO-CONTEXT-MAPPING-MIB
●CISCO-DEVICE-LOCATION-MIB ●CISCO-DHCP-SNOOPING-MIB
●CISCO-EIGRP-MIB
●CISCO-EMBEDDED-EVENT-MGR-MIB
●CISCO-ENTITY-FRU-CONTROL-MIB ●CISCO-ENTITY-SENSOR-MIB
●ENTITY-MIB ●CISCO-ERR-DISABLE-MIB
●CISCO-CONFIG-COPY-MIB ●CISCO-FLOW-MONITOR-MIB
●CISCO-FTP-CLIENT-MIB ●CISCO-HSRP-EXT-MIB
●CISCO-HSRP-MIB ●CISCO-IETF-ISIS-MIB
●CISCO-IF-EXTENSION-MIB ●CISCO-IGMP-FILTER-MIB
●CISCO-CONFIG-MAN-MIB ●CISCO-IP-CBR-METRICS-MIB
●CISCO-IPMROUTE-MIB ●CISCO-IP-STAT-MIB
●CISCO-IP-URPF-MIB ●CISCO-L2L3-INTERFACE-CONFIG-MIB
●CISCO-LAG-MIB ●CISCO-LICENSE-MGMT-MIB
●CISCO-MAC-AUTH-BYPASS-MIB ●CISCO-MAC-NOTIFICATION-MIB
●CISCO-MDI-METRICS-MIB ●CISCO-FLASH-MIB ●CISCO-OSPF-MIB
●CISCO-OSPF-TRAP-MIB ●CISCO-PAE-MIB ●CISCO-PAGP-MIB
●CISCO-PIM-MIB ●CISCO-PING-MIB ●CISCO-PORT-QOS-MIB
●CISCO-PORT-SECURITY-MIB●CISCO-PORT-STORM-CONTROL-MIB
●CISCO-POWER-ETHERNET-EXT-MIB ●CISCO-PRIVATE-VLAN-MIB
●CISCO-PROCESS-MIB ●CISCO-PRODUCTS-MIB●CISCO-RF-MIB
●CISCO-RTP-METRICS-MIB ●CISCO-RTTMON-MIB
●CISCO-SMART-INSTALL-MIB●CISCO-SNMP-TARGET-EXT-MIB ●CISCO-STACKMAKER-MIB
●CISCO-MEMORY-POOL-MIB ●CISCO-STP-EXTENSIONS-MIB
●CISCO-SYSLOG-MIB ●CISCO-TCP-MIB ●CISCO-UDLDP-MIB
●CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB ●CISCO-VLAN-MEMBERSHIP-MIB ●CISCO-VTP-MIB ●EtherLike-MIB
●HC-RMON-MIB ●IEEE8021-PAE-MIB ●IEEE8023-LAG-MIB
●IF-MIB ●IGMP-MIB ●IGMP-STD-MIB ●IP-FORWARD-MIB
●IP-MIB ●IPMROUTE-STD-MIB ●LLDP-EXT-MED-MIB
●LLDP-MIB ●NOTIFICATION-LOG-MIB
●OLD-CISCO-MEMORY-MIB ●CISCO-CDP-MIB
●POWER-ETHERNET-MIB ●RMON2-MIB
●RMON-MIB ●SNMP-COMMUNITY-MIB ●SNMP-FRAMEWORK-MIB
●SNMP-MPD-MIB ●SNMP-NOTIFICATION-MIB ●SNMP-PROXY-MIB
●SNMP-TARGET-MIB ●SNMP-USM-MIB ●SNMPv2-MIB
●SNMP-VIEW-BASED-ACM-MIB ●TCP-MIB ●UDP-MIB
●CISCO-IMAGE-MIB ●CISCO-STACKWISE-MIB
●AIRESPMACE-WIRELESS-MIB ●CISCO-LWAPP-IDS-MIB
●CISCO-LWAPP-AP-MIB ●CISCO-LWAPP-CCX-RM-MIB
●CISCO-LWAPP-CLIENT-ROAMING-MIB
●CISCO-LWAPP-DOT11-CCX-CLIENT-DIAG-MIB
●CISCO-LWAPP-DOT11-CCX-CLIENT-MIB
●CISCO-LWAPP-DOT11-CLIENT-CCX-REPORTS-MIB
●CISCO-LWAPP-DOT11-CLIENT-MIB ●CISCO-LWAPP-DOT11-MIB
●CISCO-LWAPP-DOWNLOAD-MIB ●CISCO-LWAPP-LINKTEST-MIB
●CISCO-LWAPP-MFP-MIB ●CISCO-LWAPP-MOBILITY-EXT-MIB
●CISCO-LWAPP-QOS-MIB ●CISCO-LWAPP-REAP-MIB●CISCO-LWAPP-ROGUE-MIB ●CISCO-LWAPP-RRM-MIB
●CISCO-LWAPP-SI-MIB ●CISCO-LWAPP-TSM-MIB
●CISCO-LWAPP-WLAN-MIB ●CISCO-LWAPP-WLAN-SECURITY-MIB |
Technical Support and Services |
● Cisco SMARTnet Service ● Cisco Smart Foundation Service ● Cisco SP Base Service ● Cisco Focused Technical Support Services |
Environmental Ranges |
With AC power supply
Operating environment and altitude |
Operating temperature up to 5000 ft (1500 m) |
23ºF to 113ºF / -5ºC to +45ºC |
Operating temperature up to 10,000 ft (3000 m) |
23ºF to 104ºF / -5ºC to +40ºC |
Short-term exception at sea level with single fan failure |
23ºF to 113ºF / -5ºC to +45ºC |
Short-term exception up to 5000 feet (1500 m) |
23ºF to 122ºF / -5ºC to 50ºC |
Short-term exception up to 10,000 feet (3000 m) |
23ºF to 113ºF / -5ºC to 45ºC |
With DC power supply
Operating environment and altitude (NEBS) |
Operating temperature up to 6000 ft (1800 m) |
23ºF to 113ºF / -5ºC to +45ºC |
Operating temperature up to 10,000 ft (3000 m) |
23ºF to 104ºF / -5ºC to +40ºC |
Operating temperature up to 13,000 ft (4000m) |
23ºF to 95ºF / -5ºC to 35ºC |
Short-term exception up to 6,000 feet (1800 m) |
23ºF to 131ºF /-5ºC to +55ºC |
Short-term exception up to 10,000 feet (3000 m) |
23ºF to 122ºF / -5ºC to +50ºC |
Short-term exception up to 13,000 feet (4000 m) |
23ºF to 113ºF / -5ºC to +45ºC |
Short-term exception at sea level with single fan failure |
23ºF to 113ºF / -5ºC to +45º |
Storage environment |
-40ºF to 160ºF / -40ºC to 70ºC |
Operating altitude |
Up to 5000m |
Storage altitude |
Up to 5000m |
Operating relative humidity |
5% to 96% noncondensing |
Storage relative humidity |
5% to 96% noncondensing |
Short-term exception at sealevel with single fan failure |
23ºF to 113ºF / -5ºC to +45º |
Storage environment |
-40ºF to 160ºF / -40ºC to 70ºC |
Operating altitude |
Up to 4000m |
Storage altitude |
Up to 4573m |
Operating relative humidity |
10% to 95% noncondensing |
Storage relative humidity |
10% to 95% noncondensing |